Download PDFOpen PDF in browserA Comparative Study of Effectiveness of Steel Plate Shear Wall Patterns in Steel Building6 pages•Published: July 22, 2017AbstractSteel buildings prone to lateral loads responds well if provided with SPSW. SPSW is more effective for lateral loads as they are more ductile, lighter and lesser space occupants. SPSW systems are used in high-rise buildings as retrofitting also. Now a days conventional SPSW are more preferred in steel buildings. By keeping the view in mind, an effort has been made to check the effectiveness of different patterns of SPSW. For the same, bare-frame is compared with Conventional SPSW, X–type SPSW and Diagonal SPSW. Strip modelling is used to analyse SPSW in building using ETABS software. The load considered are primary loads and earthquake load as Static coefficient method from IS 1893:2002. The maximum displacement and axial forces are compared to get effective pattern.Keyphrases: high rise buildings, lateral load resisting system, steel plate shear wall, strip modelling In: C. D. Modhera, G. J. Joshi, D.P Soni, Indrajit N. Patel, A. K. Verma, L. B. Zala, S. D. Dhiman, D. R. Bhatt, Jagdish M. Rathod, Bhargav C. Goradiya, Mehfuza S. Holia and Dharita K. Patel (editors). ICRISET2017. International Conference on Research and Innovations in Science, Engineering and Technology. Selected Papers in Civil Engineering, vol 1, pages 502-507.
|